Boca Raton Dock Rules for Repairs and Rebuilds
Boca Raton dock rules live in Chapter 22 of the City Code and in the city's Engineering Design Standards Manual. The manual's waterway section is one page, and it names docks directly.
Section 7.7 of the design manual
The city lists this section on its Seawalls and Marine Structures page as updated in January 2025. Here is the text as printed.
7.7 MINIMUM CRITERIA FOR WATERWAY FEATURES
The City’s Coastal Management Section Policy CM.1.1.11 includes enforcement of construction standards which minimize impacts of man-made structures on beach or dune systems. The minimum design criteria and layout of waterway features in this section applies to harbors, docks, bulkheads and seawalls.
Boat travel in coastal waters is a public right established through the commerce clause of the U.S. Constitution which gives Congress regulatory power over navigable waters. This authority that has been delegated to the U.S. Army Corps of Engineers (USACE). The USACE has published engineering manuals on topics such as Coastal Engineering, Shore Protection, Revetments, Seawalls, and Bulkheads, which can be used by the EOR for reference.
Design parameters are provided per Section 22 Marine Structures of the City Code and the American Society of Civil Engineers Manual of Practice No. 50 for Harbors and Docks, which can be used by the EOR for reference. The following standards reflect the ability to maintain a sustainable design with changing climate conditions:
1. The minimum elevation of any new or replaced seawall or dock (publicly or privately owned) is 4.0 feet NAVD88. The maximum elevation shall be 6.0 feet NAVD88.
2. The seawall shall be designed and constructed to harmonize with the adjacent grades and seawalls.
3. The seawall shall be designed and constructed to allow for an additional height of 12-18 inches be added in the future and remain structurally sound without alteration to the existing wall.
4. Hybrid shoreline infrastructure which incorporates gray features, such as seawalls, and living or nature-based elements should be considered.
7.7.1 CONSTRUCTION WITHIN THE WATERWAY
1. The determination of the bulkhead lines along all shores of the Intercoastal Waterway (F.E.C. Canal), the easterly shore of Lake Wyman, and Lake Boca Raton are established per Sec. 22-31 and 22-32 of the City Code.
2. Single family residential lots may have freestanding docks protruding no more than 6-8 feet water ward of the seawall (depending on the width of the canal refer to Section 22-58 of the City Code).
3. All structures must be placed within an area defined by projected lines extending water ward at a 45-degree angle from the property’s seawall at the side property lines.
4. Seawalls and bulkheads shall not be constructed beyond the property line. The section view of seawall components depicts key elements to be identified on the engineering drawings. The water side face (i.e. wet face) being on the property line per Sec. 26-146 of the City Code as depicted on the following example section.
Pulled Nov. 21, 2026. The manual follows this with a seawall section drawing on page 33.
Reading it with a repair in mind
Item 1 is the one people miss. It sets a 4.0 foot NAVD88 minimum and a 6.0 foot maximum for a new or replaced dock. If the old deck sits lower, a full replacement may have to come up.
Does your job count as a replacement or a repair? That's a question for the contractor and the city's plan reviewer, not for us.
How far out can it go? Item 2 of 7.7.1 says 6 to 8 feet past the seawall for a freestanding dock on a single family lot, depending on canal width. On a narrow or angled lot, the 45 degree side lines in item 3 can be what limits the layout.
The bulkhead lines in item 1 cover the Intracoastal, the east shore of Lake Wyman and Lake Boca Raton.
Where the code text is
Chapter 22 is published on Municode. We haven't reproduced it here. The manual points to Sections 22-31, 22-32, 22-58 and 26-146 if you want the source. For what a permit involves, see the dock repair permit page.